Tia portal word to int

If you are looking for convert word to int tia portal, simply check out our links below :

1. Convert – WORD to INT – Entries – Forum – Industry Support …

https://support.industry.siemens.com/tf//WW/en/posts/convert-word-to-int/92040?page=0&pageSize=10
Convert - WORD to INT - Entries - Forum - Industry Support ...
I´m moving the byte of hout to a variable called #HOUR. Next, i´m comparing #HOUR with another value (INT) inputed for the user. But the…

2. Convert Word to Integer in S7 – Entries – Forum – Industry …

https://support.industry.siemens.com/tf/ww/en/posts/convert-word-to-integer-in-s7/23783?page=0&pageSize=10

I am beginner in Simatic S7.I was using codesys before.I would like to know how to convert Word to Integer in S7 in ladder and also vice versa.

3. HOW CONVERT WORD TO INT ?? pls – Entries – Forum …

https://support.industry.siemens.com/tf//WW/en/posts/how-convert-word-to-int-pls/88303?page=1&pageSize=10

Yes Ton Verra,I have agree with u, becauz when i set on OP7 Hexadecimal format in input and Duel the system work good and i can use…

4. Convert word to integer sign to real. – Entries – Forum …

https://support.industry.siemens.com/tf//WW/en/posts/convert-word-to-integer-sign-to-real/88258?page=0&pageSize=10

Hi guys,I have this problem, as I can convert a word to a signed integer and this a real?. I am using v11 sp2 TIA Portal and an S7-300.

5. convert word to real – Entries – Forum – Industry Support …

https://support.industry.siemens.com/tf/ww/en/posts/128197/

(e.g. STEP7, TIA Portal etc.) … do NOT convert Word to Double Int UNLESS You are sure that value … CODE for conversion from Integer Word.

6. S7 Convert Word to Signed Integer – PLCS.net – Interactive Q …

http://www.plctalk.net/qanda/showthread.php?t=88412

23 Jun 2014 – I may be being a bit slow here but is there any way in Step 7 that you can convert a Word value to a signed integer value? Am sure its possible…

7. Convert WORD to INT – CODESYS Talk

https://forum.codesys.com/viewtopic.php?t=8370

5 Dec 2017 – It is there as a built in function. The help groups all of the integer conversions together under the section ‘conversion->integer data type’. Just start…

8. convert real to word (800xA Engineering Freelance …

https://forum-controlsystems.abb.com/3064347/convert-real-to-word

the mod slave accept only word value and no convert from real to word directly only (int,dint and STR) since the mention type didn’t send the point value (for ex.

9. Siemens S7 SCL cheat sheet – plc4good

http://plc4good.org.ua/files/03_downloads/SCL_table/SCL-cheat-sheet.pdf

Conversion. Class A. BOOL_TO_BYTE … Siemens S7. SCL cheat sheet. Numeric. ABS. Number. SQR. Square. SQRT. Square Root. EXP … WORD. W#16#0000. W#16#FFFF word#16#f. WORD#8#177777. 8#177777. W#2#1001_0100.

10. Converting DINT -> INT in S7 | Automation & Control …

https://control.com/forums/threads/converting-dint-int-in-s7.10161/

25 Nov 2002 – … lower than 65000. How to convert this DINT number to INT? … Use the least significant two bytes of the double word value. For example, if the…

11. Siemens PLC programming: BCD, Integer, Double Integer, Real

Siemens PLC programming: BCD, Integer, Double Integer, Real

Siemens PLC programming: BCD to Integer, Integer to BCD, Integer to … Bool (1 Bit), integer (16 bit), Word (16 bit), Double Integer (32 bit) and Real (32 bit). … Integer to BCD instruction is used to convert integer format to BCD coded numbers.

12. Converting real to 2 words (or one dword) – PLCnext Community

https://www.plcnext-community.net/en/discussions-2-offcanvas/converting-real-to-2-words-or-one-dword.html

22 Feb 2019 – My question is how correctly convert my real to dword without losses. … The number will be rounded to the nearest integer and the decimal part…

Related

Помогите преобразовать

obok

Любитель
Сообщения: 53
Зарегистрирован: 10 апр 2018, 20:16

Помогите преобразовать

Помогите пожалуйста!
Имеется удаленный модуль с 4 входами, соединяется с контроллером по RS485 через modbus
О замкнутых контактах на входе модуль сообщает Битовой маской значений входов, он присылает число от 0 до 15

где 0 — нет замкнутых контактов, 15 замкнуты все поясняю:

Присылаемое число 1 — замкнут контакт номер 1 что соответствует (в двоичной системе) — 1
Присылаемое число 2 — замкнут контакт номер 2 что соответствует (в двоичной системе) — 10
Присылаемое число 3 — замкнут контакт номер 1 и 2 что соответствует (в двоичной системе) — 11
Присылаемое число 4 — замкнут контакт номер 1 что соответствует (в двоичной системе) -100
Присылаемое число 8 — замкнут контакт номер 1 что соответствует (в двоичной системе) — 1000
…..
Присылаемое число 15 замкнуты все контакты что соответствует (в двоичной системе) — 1111

т.е. кажый контакт соответствует 0 или 1 у входа контакта модуля, и это регистр у двоичного числа
Так вот ….
Помогите как мне из полученного числа «Х» (в десятичной системе) перевести его в двоичную и понять 1 или 0 стоит в соответствующем регистре?

Примерно это должно выглядеть как то так (в SCL):
Вход1:= Взять_регистр 1 ( Преобразовать_в_двоичный код (Х) )
Вход2:= Взять_регистр 2 ( Преобразовать_в_двоичный код (Х) )
Вход3:= Взять_регистр 3 ( Преобразовать_в_двоичный код (Х) )
Вход4:= Взять_регистр 4 ( Преобразовать_в_двоичный код (Х) )

где Вход тип (bool), а у X тип (int)

Пожалуйста помогите как это записать в SCL?


Аватара пользователя

Ka3ax

Специалист
Сообщения: 303
Зарегистрирован: 07 сен 2013, 10:09

Re: Помогите Перобразовать

Сообщение

Ka3ax » 25 сен 2018, 00:44

смутно задача описана.

Вход1:= Взять_регистр 1 ( Преобразовать_в_двоичный код (Х) )

входу присвоить?
и здесь не ясно

Присылаемое число 4 — замкнут контакт номер 1 что соответствует (в двоичной системе) -100
Присылаемое число 8 — замкнут контакт номер 1 что соответствует (в двоичной системе) — 1000

отчего «страдает» всегда первый контакт? ожидаемые контакты 4 и 8
исхожу из

где 0 — нет замкнутых контактов, 15 замкнуты все поясняю:

в scl имеются команды int_to_bool bool_to_word, SHR, SHl
можно двигать и маскировать

Код: Выделить всё

VAR_INPUT
    Input_word:           WORD;
    
END_VAR
VAR
    
    comp_1_in:              INT;
    comp_2_in:              INT;
    temp:       bool;
END_VAR

    BEGIN;
    
    comp_1_in     := Input_word AND w#16#ff;
    comp_2_in := Input_word AND w#16#00ff SHR(in:=Input_word, N:=8); 

или двигать и младший бит считывать

Код: Выделить всё

temp := int_to_bool( SHR(in:=Input_word, N:=8))

или слайс. в TIA

Код: Выделить всё

temp := Input_word.%x1 
temp12 := Input_word.%x11
 

все через case реализовать

ps
пока отвечал. понял, что входящяя переменная int тип.
тогда расскладываем по битам int_to_word и далее один из вышеприведенных принципов.
только вместо
temp := int_to_bool( SHR(in:=Input_word, N:=8))
temp := word_to_bool( SHR(in:=Input_word, N:=8))
извиняйте. засыпаю :)

Supervision of erection


Михайло

Администратор
Сообщения: 4073
Зарегистрирован: 19 сен 2012, 19:16

Re: Помогите преобразовать

Сообщение

Михайло » 25 сен 2018, 06:25

obok писал(а):где Вход тип (bool), а у X тип (int)

Вместо INT используйте тип WORD, INT — для хранения числовых значений, WORD — для наборов отдельных битов (как в вашем случае).

Ну и как написал Ка3ах:
Вход0:= Х.x0;
Вход1:= Х.x1;
Вход2:= Х.x2;
Вход3:= Х.x3;

Вход15:= Х.x15;


obok

Любитель
Сообщения: 53
Зарегистрирован: 10 апр 2018, 20:16

Re: Помогите преобразовать

Сообщение

obok » 25 сен 2018, 08:23

Михайло писал(а):

obok писал(а):где Вход тип (bool), а у X тип (int)

Вместо INT используйте тип WORD, INT — для хранения числовых значений, WORD — для наборов отдельных битов (как в вашем случае).

Ну и как написал Ка3ах:
Вход0:= Х.x0;
Вход1:= Х.x1;
Вход2:= Х.x2;
Вход3:= Х.x3;

Вход15:= Х.x15;

СПАСИБО! То что нужно!

Извините, что смутно описал проблему не знал как это объяснить.


obok

Любитель
Сообщения: 53
Зарегистрирован: 10 апр 2018, 20:16

Re: Помогите преобразовать

Сообщение

obok » 25 сен 2018, 08:38

Еще подскажите как правильно это записать в цикле, я записываю так но у меня компилятор ругается см. картинку

У вас нет необходимых прав для просмотра вложений в этом сообщении.


Аватара пользователя

Ka3ax

Специалист
Сообщения: 303
Зарегистрирован: 07 сен 2013, 10:09

Re: Помогите преобразовать

Сообщение

Ka3ax » 25 сен 2018, 09:00

а никак :D
слайст не работает в цикле, я недавно бегал, сам спрашивал как.
тупо 16 значений прописать и все, что сименс в своих примерах тоже делает.
или через оверлей AT и массив к битам обращаться.
но в Вашем случае проще 1 раз прописать 16 бит

Supervision of erection


obok

Любитель
Сообщения: 53
Зарегистрирован: 10 апр 2018, 20:16

Re: Помогите преобразовать

Сообщение

obok » 25 сен 2018, 12:13

Ka3ax писал(а):а никак :D
слайст не работает в цикле, я недавно бегал, сам спрашивал как.
тупо 16 значений прописать и все, что сименс в своих примерах тоже делает.
или через оверлей AT и массив к битам обращаться.
но в Вашем случае проще 1 раз прописать 16 бит

Спасибо, а то бился не мог понять, что же не правильно пишу и кавычки ставил и скобки, и фигурные скобки …. вобщем не мог я сдаться, а оказалось так просто нельзя))) :wall:


Old
March 1st, 2015, 05:50 PM

 
#1

Lifetime Supporting Member

Australia

ASF is offline

 

Join Date: Jun 2012

Location: Australia

Posts: 3,694

Copy Word to Struct — TIA Portal


Hi all,

Straight up question: I’m using TIA Portal and an S7-1200, and wanting to do a straight bitwise copy of all the data in a Word to put it into a Struct (which consists of a byte and 8 bools). Is there a way to do this? I’ve tried all the instructions that I can think of, but they all give me data type mismatches.

Context (in case there’s a better way to approach what I’m doing): I’m getting a 16-bit integer coming in from a Modbus TCP device, and this particular status word contains:
— Bit 0-7: Value 1
— Bit 8-12: Value 2
— Bits 13, 14 and 15: status bits
I can bring it straight into a Struct tag of one byte and 8 bools, but then I have no easy way of re-assembling the value from Bits 8-12 back into a meaningful value. So I decided to bring it into an Int. Then I can use AND’s and bit shift instructions to extract Value 1 and Value 2, and all I have to do then is extract the Bool’s.

I can think of two ways to do this:

1. Address the bit within the Int: e.g. just use %DB331.DBX2.13 to turn on a coil. That coil becomes my bool. This works, but gives me IEC warnings

2. Move the Int into an M word (e.g. MW100) and then address (e.g.) M100.5 to get my Bool. Which also works

And while they both work, I’m thinking it would still be much simpler if I could just do a straight copy. Is it possible, or should I just pick one of my two options above and move on?

Thanks!

 

Reply With Quote

Old
March 1st, 2015, 05:59 PM

 
#2

Lifetime Supporting Member

Australia

ASF is offline

 

Join Date: Jun 2012

Location: Australia

Posts: 3,694

I’ve just worked out that I can use a MOVE instruction if I specify the word in the DB by it’s offset, rather than it’s name (MOVE DB331.DBW6 to DB331.DBW18), but again, I get an IEC warning. So if there’s a more elegant solution I’m eager to hear it

 

Reply With Quote

Old
March 1st, 2015, 10:15 PM

 
#3

Lifetime Supporting Member

United States

mk42 is offline

 

Join Date: Jun 2013

Location: MI

Posts: 2,924

As far as I know, Siemens doesn’t have any 5 bit data types, so your structure couldn’t match up exactly. I don’t think a straight copy is possible.

One other way to address the values within the tag in the 1200 is to use what they call «slice» addressing. If you address the memory location by name, you can append «.B0» to mean the least significant byte, «.X3» to grab the 4th bit (counting from 0), etc. So you could copy out the first value from «Datablock.tagname.B0», to do it symbolically, and not have to deal with the offsets. You could use .X15, or possibly .B1.X7 to grab one of the status bits at the end.

The above might avoid the IEC error, but you still have the same issues with the 5 byte value. In the end, you still have to do something like one of the ideas you already had.

 

Reply With Quote

Old
March 1st, 2015, 10:56 PM

 
#4

Lifetime Supporting Member

Australia

ASF is offline

 

Join Date: Jun 2012

Location: Australia

Posts: 3,694

Thanks for the response. I’m currently using the «.X3» to grab the bool’s individually (DB331.DBX1.3), and it works, but still gives me the IEC error.

As far as the five bit data type, that’s not an issue — I just get the whole Int and run it through an AND and a Bit Shift, and store it in another Int. Now I just want to try and grab the bool’s — preferably without generating an IEC error

 

Reply With Quote

Old
March 2nd, 2015, 01:20 AM

 
#5

Lifetime Supporting Member

Sweden

rQx is offline

 

Join Date: Oct 2010

Location: Trelleborg

Posts: 1,000

You seem to have in a non optimized DB, if you move your incomoing value to a DB with optimized settings you can use bitslicing without error. Example:

Move your value to DB10 and name it MODBUS

Then just adress it MODBUS.X0 to access the first bit.
MODBUS.B0 for first byte
MODBUS.W0 for first word.

https://support.industry.siemens.com…74718?lc=en-WW

 

Reply With Quote

Old
March 2nd, 2015, 07:16 PM

 
#6

Lifetime Supporting Member

Australia

ASF is offline

 

Join Date: Jun 2012

Location: Australia

Posts: 3,694

Aha, that works nicely!

Just to dot the i’s and cross the t’s, the addressing format is:

[DB Name].[Element Name].x[Bit Number]

e.g. Weight_TX_Data.Status_Word.x13 where Weight_TX_Data is the DB, Status_Word is a Word tag in the DB, and I’m addressing bit 13 of Status_Word.

Thanks!

 

Reply With Quote

Old
March 3rd, 2015, 01:46 AM

 
#7

Lifetime Supporting Member

Sweden

rQx is offline

 

Join Date: Oct 2010

Location: Trelleborg

Posts: 1,000

Yes, that’s correct! The optimized datablocks are overall better to use so try to use optimized rather then the non optimized. Sometimes you must use the non-optimized for communication etc as you might know

 

Reply With Quote

Old
March 3rd, 2015, 02:25 AM

 
#8

Member

Belgium

Jeebs is offline

 

Join Date: Feb 2007

Location: Leuven

Posts: 1,059

But what if one wants to do:
Weight_TX_Data.Status_Word.Enabled
In stead of:
Weight_TX_Data.Status_Word.X13

 

Reply With Quote

Old
March 3rd, 2015, 04:14 AM

 
#9

Lifetime Supporting Member

Sweden

rQx is offline

 

Join Date: Oct 2010

Location: Trelleborg

Posts: 1,000

How do you mean? What is «enabled», I know the word but what do you want to do?

 

Reply With Quote

Old
March 3rd, 2015, 05:10 AM

 
#10

Member

Belgium

Jeebs is offline

 

Join Date: Feb 2007

Location: Leuven

Posts: 1,059

Give .X13 a symbolic name and use it by its symbolic name.

 

Reply With Quote

Old
March 3rd, 2015, 05:22 AM

 
#11

Lifetime Supporting Member

Sweden

rQx is offline

 

Join Date: Oct 2010

Location: Trelleborg

Posts: 1,000

Ah, I don’t think you can do that since we only «slice» the word into bits in the ladder. The bits we access isn’t specified anywhere in any DB. At least as far as I know.

 

Reply With Quote

Old
March 3rd, 2015, 07:52 AM

 
#12

Member

United Kingdom

Manglemender is offline

 

Join Date: Jul 2007

Location: Lancashire

Posts: 1,260

I haven’t used TIA portal much but does it not support UDTs?

The conventional way to handle this would be to create a UDT with the structure that corresponds to the slave data and then transfer said data into an instance of the UDT.

Nick

 

Reply With Quote

Old
March 3rd, 2015, 05:26 PM

 
#13

Lifetime Supporting Member

Australia

ASF is offline

 

Join Date: Jun 2012

Location: Australia

Posts: 3,694

Jeebs, what rQx said is correct — the Status tag is an Int, so I can’t give each bit a symbolic name. I could make it a STRUCT tag with individual bools, and do that, but then I’m back to my previous problem of getting 5 Bool’s packed back into an Int (see original post)

Manglemender — yes, I could create a UDT, but then I’m still stuck in the same place — how do I get my data into it? The biggest problem here was not that I need to extract 16 bits out of an Int — if it were 16 individual bits, I’d have just created a Struct tag with 16 bools, brought the data straight into there, and I’d already be at the pub. The problem is because I have 16 bits of information where the first 8 bits are to be read as a decimal value, the next 5 bits are to be read as a decimal value, and then the next three bits are to be read as individual bools. As mk42 said, there’s no 5-bit data type in Siemens, so I can’t create a UDT to fit them all into the right place.

In any case, with the information in posts 5-7, I’ve got what I needed. Thanks everyone!


Last edited by ASF; March 3rd, 2015 at 05:29 PM.

 

Reply With Quote

Old
March 4th, 2015, 07:37 PM

 
#14

Member

Netherlands

wimpiesplc is offline

 

Join Date: Feb 2012

Location: Netherlands

Posts: 344

can’t you use library function BLKMOV (SFC20) ?

 

Reply With Quote

Old
March 5th, 2015, 03:32 AM

 
#15

Member

United Kingdom

BryanG is offline

 

Join Date: Feb 2005

Location: Manchester

Posts: 1,866

I was thinking POKE_BLK, it doesn’t care about data types, but I don’t know if it would be acceptable under IEC’what do you call it’.

 

Reply With Quote

  1. Обязательно представиться на русском языке кириллицей (заполнить поле «Имя»).
  2. Фиктивные имена мы не приветствуем. Ивановых и Пупкиных здесь уже достаточно.
  3. Не писать свой вопрос в первую попавшуюся тему — вместо этого создать новую тему.
  4. За поиск, предложение и обсуждение пиратского ПО и средств взлома — бан без предупреждения.
  5. Рекламу и частные объявления «куплю/продам/есть халтура» мы не размещаем ни на каких условиях.
  6. Перед тем как что-то написать — читать здесь и здесь.

RoninX

здесь недавно
здесь недавно
Сообщения: 8
Зарегистрирован: 08 авг 2018, 21:27
Имя: Павел
Страна: Россия
город/регион: Москва
Благодарил (а): 3 раза

Склеить два Word и получить Real

Сообщение

RoninX » 08 авг 2018, 21:46

Здравствуйте!

Измеритель выдает значение влажности в формате Real IEEE754 двумя Word. Связь с измерителем по интерфейсу RS485 Modbus RTU. Контроллер S7-1200. Как в TIA portal преобразовать эти два регистра WORD в REAL? (CD AB). На контроллерах Овен задача решается путем создания типа FLoat в списке регистров Модбас и контроллер сам преобразовывает два регистра в Реал. Как данная задача решается в tia portal v4.2?

pkl58

не первый раз у нас
не первый раз у нас
Сообщения: 347
Зарегистрирован: 19 мар 2012, 20:04
Имя: Павел
Страна: Россия
Благодарил (а): 5 раз
Поблагодарили: 43 раза

Склеить два Word и получить Real

Сообщение

pkl58 » 09 авг 2018, 12:41

Как у Сименса не знаю. Но в общем случае есть команды преобразования целых чисел в вещественные. Возможно потребуется поменять местами исходные WORD.

NewOrdered

осмотрелся
осмотрелся
Сообщения: 153
Зарегистрирован: 24 янв 2018, 11:18
Имя: Антон
Страна: Россия
город/регион: Калининград
Благодарил (а): 25 раз
Поблагодарили: 25 раз

Склеить два Word и получить Real

Сообщение

NewOrdered » 09 авг 2018, 13:49

RoninX писал(а): ↑08 авг 2018, 21:46
Здравствуйте!

Измеритель выдает значение влажности в формате Real IEEE754 двумя Word. Связь с измерителем по интерфейсу RS485 Modbus RTU. Контроллер S7-1200. Как в TIA portal преобразовать эти два регистра WORD в REAL? (CD AB). На контроллерах Овен задача решается путем создания типа FLoat в списке регистров Модбас и контроллер сам преобразовывает два регистра в Реал. Как данная задача решается в tia portal v4.2?

Определите область памяти длиной 4 байта как REAL. В первые два байта загрузите 1 слово, во вторые — второе слово. Далее работайте с вашим значением в формате REAL.

RoninX

здесь недавно
здесь недавно
Сообщения: 8
Зарегистрирован: 08 авг 2018, 21:27
Имя: Павел
Страна: Россия
город/регион: Москва
Благодарил (а): 3 раза

Склеить два Word и получить Real

Сообщение

RoninX » 14 авг 2018, 10:30

NewOrdered писал(а): ↑09 авг 2018, 13:49
Определите область памяти длиной 4 байта как REAL. В первые два байта загрузите 1 слово, во вторые — второе слово. Далее работайте с вашим значением в формате REAL.

Добрый день! Получилось, спасибо!

djonm

новенький
новенький
Сообщения: 1
Зарегистрирован: 07 фев 2018, 15:04
Имя: Евгений
город/регион: Ростов

Склеить два Word и получить Real

Сообщение

djonm » 22 авг 2018, 13:53

RoninX писал(а): ↑14 авг 2018, 10:30
Добрый день! Получилось, спасибо!

У меня похожая задача и что то не фига не получается. По modbus читаю значение измеренного напряжения float32 (real). MB_Master читает в переменную REAL, но значение получаются совсем левые. Может надо читать Word- дами а потом переставлять биты и конвертировать в REAL?

Аватара пользователя

petr2off

эксперт
эксперт
Сообщения: 1356
Зарегистрирован: 06 янв 2016, 19:45
Имя: Петров В.Л.
Страна: Россия
город/регион: Красноярск
Благодарил (а): 56 раз
Поблагодарили: 138 раз

Склеить два Word и получить Real

Сообщение

petr2off » 22 авг 2018, 16:33

Какая разница как читать, Вы уже считали 4 байта. К этой области памяти можно обратится как 4-х байтовому полю, как к 2 16-ти битовым словам и как к 4 байтовым адресам. А еще добавляя точку можно и к битам обратится. Как вариант поменяйте слова местами. Очень часто при чтении Modbas 16 разрядные слова не в том порядке принимаются.

RoninX

здесь недавно
здесь недавно
Сообщения: 8
Зарегистрирован: 08 авг 2018, 21:27
Имя: Павел
Страна: Россия
город/регион: Москва
Благодарил (а): 3 раза

Склеить два Word и получить Real

Сообщение

RoninX » 24 дек 2018, 14:44

[/quote] У меня похожая задача и что то не фига не получается. По modbus читаю значение измеренного напряжения float32 (real). MB_Master читает в переменную REAL, но значение получаются совсем левые. Может надо читать Word- дами а потом переставлять биты и конвертировать в REAL?
[/quote]

Попробуйте применить функцию SWAP

Serg_G

здесь недавно
здесь недавно
Сообщения: 59
Зарегистрирован: 04 авг 2018, 07:02
Имя: Сергей
Благодарил (а): 8 раз
Поблагодарили: 2 раза

Склеить два Word и получить Real

Сообщение

Serg_G » 21 янв 2019, 18:45

Попробуйте так. В классике это работало. Только надо правильно выбрать байты из слова.

У вас нет необходимых прав для просмотра вложений в этом сообщении.

Вернуться в «Simatic TIA Portal»


Перейти

  • Работа форума
  • База знаний (Knowledge Exchange)
  • ↳   Eplan Electric P8
  • ↳   Общий F.A.Q.
  • ↳   Общие вопросы
  • ↳   Новости
  • ↳   Ошибки
  • ↳   Проект
  • ↳   Изделия
  • ↳   Устройства
  • ↳   Соединения
  • ↳   Кабели
  • ↳   Клеммы
  • ↳   ПЛК
  • ↳   Компоновка 2D
  • ↳   Макросы
  • ↳   Eplan API
  • ↳   Сценарии (Только готовые решения)
  • ↳   Внешняя обработка
  • ↳   ProPanel
  • ↳   Инструкции ProPanel (Только готовые решения)
  • ↳   Прочие направления Eplan
  • ↳   FieldSys (Топология)
  • ↳   Preplanning
  • ↳   Harness proD
  • ↳   EEC One
  • ↳   Advantech
  • ↳   F.A.Q., Инструкции
  • ↳   Allen Bradley
  • ↳   Общие вопросы
  • ↳   ПЛК
  • ↳   Операторские панели
  • ↳   B&R Automation
  • ↳   F.A.Q.
  • ↳   Danfoss
  • ↳   DEIF A/S
  • ↳   Общие вопросы
  • ↳   UNI-LINE
  • ↳   MULTI-LINE
  • ↳   MULTI-LINE 300
  • ↳   Emerson
  • ↳   Общие вопросы
  • ↳   КИП и регуляторы
  • ↳   DeltaV
  • ↳   ОВЕН
  • ↳   Прософт-Системы
  • ↳   Общие вопросы
  • ↳   ПЛК REGUL
  • ↳   Schneider Electric
  • ↳   Общие вопросы
  • ↳   ПЛК
  • ↳   Панели оператора
  • ↳   SCADA
  • ↳   Электротехника
  • ↳   Приводная техника
  • ↳   SIEMENS
  • ↳   Общие вопросы
  • ↳   LOGO!
  • ↳   ПЛК SIMATIC (S7-200, S7-1200, S7-300, S7-400, S7-1500, ET200)
  • ↳   Simatic Step7
  • ↳   Simatic TIA Portal
  • ↳   Simatic PCS 7
  • ↳   Операторские панели
  • ↳   WinCC
  • ↳   Приводная техника (Sinamics, Micromaster, Masterdrive, Simoreg, Simotics)
  • ↳   SmartGen
  • ↳   Общие вопросы
  • ↳   Промышленные (береговые) контроллеры
  • ↳   Морские контроллеры и устройства
  • ↳   WEINTEK (операторские панели)
  • ↳   F.A.Q., Инструкции
  • ↳   Архив
  • ↳   Микроконтроллеры и электроника
  • ↳   Arduino
  • ↳   Raspberry
  • ↳   Другие микроконтроллеры
  • ↳   Электроника
  • Общие вопросы АСУТП
  • ↳   Общие вопросы
  • ↳   Вопросы от студентов
  • ↳   Литература
  • ↳   Новости и отчётность
  • ↳   Нормативы, ГОСТы, стандарты
  • ↳   Информационная безопасность
  • ↳   Проектирование и САПР
  • ↳   Системная интеграция
  • ↳   Разбор полетов
  • ↳   Работа
  • ↳   Заготовки для базы знаний
  • ↳   Производство и технология
  • ↳   MES — Системы автоматизации управления производством
  • ↳   Метрология, КИП и датчики
  • ↳   Исполнительные устройства, регуляторы
  • ↳   Средний уровень автоматизации (управляющий)
  • ↳   Алгоритмы
  • ↳   Операторские панели
  • ↳   Верхний уровень автоматизации (отображение)
  • ↳   GE iFix
  • ↳   Wonderware Intouch
  • ↳   MasterScada
  • ↳   SCADA+
  • ↳   Альфа платформа
  • ↳   Интерфейсы, протоколы, связь
  • ↳   Радиосвязь
  • ↳   Полезное ПО
  • ↳   Электротехника, энергетика и электропривод
  • ↳   Генераторы, электростанции и силовые агрегаты
  • ↳   Теплотехника
  • ↳   Подбор аналогов
  • F.A.Q. (краткая выжимка из некоторых сообщений форума)
  • ↳   Документация (вариант 1)
  • ↳   Документация (вариант 2)
  • ↳   Электротехника и электроэнергетика
  • ↳   F.A.Q. по программируемым логическим контроллерам (PLC)
  • ↳   Обсуждение F.A.Q. по PLC
  • ↳   F.A.Q. по выбору PLC
  • ↳   F.A.Q. по аппаратной части PLC
  • ↳   F.A.Q. по языкам программирования
  • ↳   F.A.Q. по структуре программ
  • ↳   F.A.Q. по взаимодействию PLC с HMI
  • О жизни
  • ↳   Для дома, для семьи
  • ↳   Комната смеха
  • ↳   Электродвижение

convert bool to int tia portal access in 3 steps, tia portal hex to decimal, time to real tia portal, bit to byte tia, tia portal data types

SIEMENS S7-1200 PLC, HMI & SCADA – YouTube

convert bool to int tia portal

TIA PORTAL | Converting INT to Real – YouTube

PLC programming tutorial TIA Portal – YouTube

Python | Ways to convert Boolean values to integer

https://www.geeksforgeeks.org/python-ways-to-convert-boolean-values-to-integer/

Sep 14, 2022 — Given a boolean value(s), write a Python program to convert them into an integer value or list respectively. Given below are a few methods …

c# – How to convert bool to int efficiently? – Stack Overflow

https://stackoverflow.com/questions/66985162/how-to-convert-bool-to-int-efficiently

Apr 7, 2021 · 2 answers It’s not all that surprising that reading 4 bytes from a bool generates code that spills to memory first, then reloads, because that’s a …

TIA Portal data types and conversions – OB121

https://www.ob121.com/doku.php?id=de:s7:tia_datatypes

BOOL #0 or BOOL #1 … S7-1500, 16 bit bit pattern, 16 BOOL → WORD and BYTE … the Int data type can now be converted to the Real data type („ Int to Real”).

Simple way to convert Bits to a Word – UNLIMITED USES!

Simple way to convert Bits to a Word – UNLIMITED USES! from PLC

Nov 26, 2019 — Hey guys – Are you sick of having to convert all your Boolean alarms to a Word in order to bring them into Siemens TIA built-in “HMI Alarms” …

Proficy Question – Move INT to BOOL : r/PLC – Reddit

Proficy Question – Move INT to BOOL from PLC

Dec 13, 2017 — In the second rung of the MAIN block, there is a MOVE command which moves the value of R00410 (which is a numeric value) to M00281. M00281 is a …

Read Siemens word into boolean array – Ignition

https://forum.inductiveautomation.com/t/read-siemens-word-into-boolean-array/52963

Nov 11, 2021 — This syntax is incorrect. You’re asking for bit 0 of that word, then letting Ignition turn that bool into an int , then casting that int into a …

Понравилась статья? Поделить с друзьями:
  • Those were the days song word
  • Thursday word of the day
  • Thisworkbook path vba excel
  • Thunk is not a word
  • This worksheets excel миф